NV-Reason-CT: 3D Visual Language Model for CT Analysis

Andriy Myronenko, Dong Yang, Yu-Cheng Tang, B. Turkbey, Benjamin D. Simon, S. Harmon, R. Makwana, M. Aboian, S. Azamat, I. E. Hamamci, Sezgin Er, Bjoern H Menze, Zong-Wei Zhou, Wen-Xuan Li, M. Edgar, Yu-Fan He, Peng-Fei Guo, Da-Guang Xu
arXiv.org | 2026

Reading guide · Based on sections of the original paper

The authors present NV-Reason-CT, a released chest and abdominal CT vision-language model. It passes all 13,824 3D visual tokens, with explicit depth, height and width positions, into a Qwen3.5-4B decoder. It is trained by supervised fine-tuning on about 550,000 examples, including radiologist-guided reasoning, followed by GRPO with verifiable finding rewards.

Why read this

This paper suits practitioners building volumetric medical VLMs who want an open checkpoint, training code and a carefully qualified benchmark comparison across CT-RATE, Merlin and RAD-ChestCT.

What the authors found

  • On external RAD-ChestCT, the authors evaluated all 3,630 volumes with 16 harmonized labels, a single Yes/No prompt and a fixed 0.5 threshold, with no retraining or calibration. Under these conditions they report macro-F1 0.5311 and AUROC 0.7958. The closest published comparators are CT-SSG (0.5225 F1, five-fold mean) and Pillar-0 via DCP-PD (0.497 F1, 0.796 AUROC), and evaluation protocols differ. 5.3.1 RAD-ChestCT abnormality classification
  • For CT-RATE report generation, labels extracted from generated reports give macro-F1 0.592 over 18 abnormalities. Published columns report 0.449 for COLIPRI-CRM and 0.365 for MonteRET. The authors caution that cohorts and extractors differ, so this table is not a controlled ranking. Appendix B Per-abnormality CT-RATE report-derived results
  • On Merlin abdominal 30-finding classification with balanced cohorts, the model scores macro-F1 0.7655 and AUROC 0.8329. Comparators are Merlin's 0.7410 F1 and VoxelFM's 0.7970 AUROC, which are not strictly paired. The prompt was selected on the same test cohort. 5.2.1 Merlin abnormality classification

Main limitation

All evaluations cover the complete model. No ablations isolate the 3D-coordinate interface, the reasoning supervision or GRPO. The reported 50% time saving comes from 2 radiologists reading 10 cases, with unaided review always preceding AI-assisted review. 6 Limitations

Where to start

5.1.1 CT-RATE abnormality classification · This section explains the CT-RATE classification protocol behind the 0.614 macro-F1, how the v1 and v2 cohorts are handled, and why calibrated ensembles such as AnyMC3D (0.646) are excluded.

Abstract

We present NV-Reason-CT, a generative vision--language model for chest and abdominal CT combining native 3D visual encoding with radiologist-guided reasoning. The model couples a native 3D vision transformer with a language model, passing all visual tokens and their explicit 3D coordinates into language decoding without further spatial token merging. This retains volumetric spatial information within the vision encoder and through the language model's positional encoding during joint processing with text. We train on a curated corpus of approximately 550,000 multimodal instruction examples from 70,111 unique CT image inputs, combining standardized reports, abnormality-focused and anatomy-specific questions, multi-turn interactions, and radiologist-authored reasoning from recorded and transcribed expert CT interpretations. Expert annotations provide direct supervision and guide additional report-grounded synthetic reasoning. End-to-end supervised fine-tuning (SFT) is followed by Group Relative Policy Optimization (GRPO), with verifiable rewards over chest and abdominal abnormality sets. The model supports abnormality classification, report generation, and interactive reasoning with reviewable observations, differential diagnoses, and uncertainty. Evaluation spans public CT benchmarks and a held-out NIH cohort. On CT-RATE, NV-Reason-CT achieves a macro-F1 of 0.614 and macro-AUROC of 0.871 without a task-specific classification head; generated reports achieve a report-derived macro-F1 of 0.592. In a preliminary study with expert radiologists, AI-assisted review received favorable confidence ratings and was associated with a 50% reduction in average reported interpretation and reporting time. We release the model and training code to support reproducible research on explainable AI for volumetric medical imaging.